Ezy Mechanic | Machine components and linkages design made easy.
Friday, July 3, 2015
Example of rotary indexer sizing calculation for table plate drive application (1/3)
Indexing System Information
Physical Properties Info.
Rotary Indexer with Dial Table Driving Application
Rotary Indexer with Dial Table Driving Application
Dial Table Info.
Diameter, [Ddial] = 1000 mm
Thickness, [Y] = 20 mm
Material = Aluminum (Density 0.00274 g/mm3)
Mass of dial table
Then Table Mass, [Mdial] = 43.040 Kg.
Station Info.
Number of Stations, [Nstations] = 8 stations
Mass per Station, [Mstation] = 20 Kg/staion
Then Total Station Mass, [SMstations] = 8 x 20 = 160 Kg
Rotating Radius to Station Center, [Rst] = 450 mm (If the station is large or complex shape, a radius of gyration of each station should be calculated.)
Additional Part Info. (The same part at the same rotation radius)
Number of parts, [Nadd part] = 4 parts
Part Mass, [Madd part] = 2 Kg/part
Total Additional Part Mass, [SMaddpart] = 4 x 2 = 8 Kg
Rotating Radius to Part Center, [Radd part] = 300 mm (If the part is large or complex shape, a radius of gyration of each part should be calculated.)
If there are others group of additional parts, do the same method.
Movement Info.
Rotary Indexer Movement Term
Number of Stops, [S] = 8 stops
Displacement per 1 index
Dial Plate Displacement per Index, [hm] = 2 x 3.1416 / 8 = 0.785 rad
Indexer Input Shaft Cycle, [T] = 1 sec (Assume to 1 second, this can be adjusted later)
Indexing Rate
Indexing Rate, [Nrpm] = 60/1 = 60 rpm
Indexing Period, [Bm] = 270 deg (Assume to 270 degree, should be taken as long as possible for smoother movement. Please check to the manufacturer information)
Indexing Time
Indexing Time, [tm] = 270/360 x 60/60 = 0.750 sec
Dwell Time
Dwell Time, [tdwell] = 1 - 0.750 = 0.250 sec
Required Dwell Time, [tdwell required] = 10 sec (This is actual required dwell time according to the working process.)
In case of tdwell required > tdwell we can use clutch and brake to extend the dwell period, but if tdwell required < tdwell that mean we can reduce tdwell to be the same as tdwell required
Reducing tdwell required can be consider in 2 cases. Reducing indexer input shaft cycle [T] or Increasing indexing period [Bm].
This case, tdwell required > tdwell
Motor stop time
Input Shaft Stop Time, [tstop] = 9.750 sec
Machine cycle time
Machine Cycle Time, [Tmachine] = T + tstop = 1 + 9.750 = 10.750 sec
Machine Speed, [Speedmachine] = 3600/10.750 x 8/8 = 334.884 UPH
Machine Speed
Displacement VS Indexing Angle
Cam Curve : Modified Sine (assumed, please check from rotary indexer manufacturer data)
Safety Factor, [SF] = 1.2
Operating Condition : 24 Hrs running, Steady load, Starts/stops 2 times per hour, Ambient temperature 30 C, Without cooling fan
could you please send me excel program of Rotary Indexer Sizing Calculation for Table Plate Drive Application